增广智能 - 领先的精密运动控制系统及元件提供商

回到首页
RM-NPLA-HF
SoftForce Micro Platform-type Linear Actuator
RM-NPLA-HF SoftForce® Micro Platform-type Linear Actuator

How to Order

Product Specifications

Product Model and Parameters (Applicable Sensor Range for HF50, HF100, HF200)

 
Model RM-NPLA-10-30-1-HF RM-NPLA-10-30-2-HF RM-NPLA-10-30-4-HF RM-NPLA-10-50-1-HF RM-NPLA-10-50-2-HF RM-NPLA-10-50-4-HF
Size Code 10 10 10 10 10 10
Stroke (mm) 30 30 30 50 50 50
Lead (mm) 1 2 4 1 2 4
Max.speed (mm/s) 50 100 200 50 100 200
Max. Horizontal load Mass (kg) 2 2 2 2 2 2
Max. Vertical load Mass (kg) 3 2 1 3 2 1
Repeat Positioning Accuracy (mm) ±0.005 ±0.005 ±0.005 ±0.005 ±0.005 ±0.005
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Rated Current (A) DC24±10% DC24±10% DC24±10% DC24±10% DC24±10% DC24±10%
Rated Voltage (V) 1.25 1.25 1.25 1.25 1.25 1.25
Cable Length (m) 3/5 3/5 3/5 3/5 3/5 3/5
Weight (kg) 0.7 0.7 0.7 0.8 0.8 0.8
Usage Environment 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40 IP40 IP40

 

Product Model and Parameters (Applicable Sensor Range for HF10)

 
Model RM-NPLA-10-30-2-HF10 RM-NPLA-10-30-4-HF10 RM-NPLA-10-50-2-HF10 RM-NPLA-10-50-4-HF10
Size Code 10 10 10 10
Stroke (mm) 2 4 2 4
Lead (mm) 30 30 50 50
Max.speed (mm/s) 100 200 100 200
Max. Horizontal load Mass (kg) 0.5 0.5 0.5 0.5
Max. Vertical load Mass (kg) 0.5 0.3 0.5 0.3
Repeat Positioning Accuracy (mm) ±0.005 ±0.005 ±0.005 ±0.005
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Modbus RTU,
EtherCAT,
Modbus TCP,
PROFINET,
EtherNet/IP,
CC-LINK,
CANopen
Rated Current (A) DC24±10% DC24±10% DC24±10% DC24±10%
Rated Voltage (V) 1.25 1.25 1.25 1.25
Cable Length (m) 3/5 3/5 3/5 3/5
Weight (kg) 0.7 0.7 0.8 0.8
Usage Environment 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing) 0~40°C, < 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

Closed-Loop Output Range Table for Different Sensor Ranges

Lead (mm) Stroke (mm) Closed-loop Output Range (N)
HF10-0001 HF50-001 HF100-005 HF200-010
1 30, 50 / 0.2~49.8 0.6~99.4 1.1~198.9
2 30, 50 0.02~9.98 0.2~49.8 0.6~99.4 /
4 30, 50 0.02~9.98 0.2~49.8 / /

Description

The drawings provided in this Catalog are for the default standard model. If you require other models with different motor directions, outlet directions, or outlet methods, please contact your local sales representative to obtain the drawings for the optional models.

Documentation Download

Dimension Drawing
Model Image