RM MagiFloater
How to Order
Product Specifications
![]() |
|
Model | RM-PVCS-5-15-F |
Stroke (mm) | 15 |
Continuous Force1 (N) | 5 |
Force Constant (N/A) | 2.85 |
Repeat Positioning Accuracy (mm) | ±6 |
Linear Travel Resolution (μm) | 0.5 |
Max. frequency (Hz) | 6 |
Compatible Controllers | RM-CEPF-20、RM-CEUF-55、RM-CEMF-55 |
Supporting Bus Protocols | Modbus RTU,EtherCAT,Modbus TCP,PROFINET,EtherNet/IP,CC-LINK,CANopen |
Rated Current (A) | 2.1 |
Rated Voltage (V) | 24 |
Z-axis Anti-drop Protection | Constant Force Spring Reset |
Cable Length (m) | 3 |
Weight (kg) | 1.1 |
Usage Environment | 0~40°C, < 85%RH (Non-condensing) |
Protection Class IP | IP40 |
Closed-Loop Output Range Table for Different Sensor Ranges
Continuous Force (N) | Stroke (mm) | Closed-loop Output Range (N) | |||
HF10-0001 | |||||
5 | 15 | 0.04~4.96 |
Description
The drawings provided in this product manual are for the standard configurations by default. Should you require alternative models with different motor directions, wiring directions, or wiring methods, please contact your local sales representative to obtain the drawings for the selected configurations.
Documentation Download